GISE Home G250 is a ready-to-install operator kit for double swing gates with an opening width of up to 5 m. In the control unit, the movement force, the slowdown position in percent and the resistance at which the gate reverses its direction are set digitally. Photocells are not included in the kit.
Main features
- Designed for double swing gates with an opening width of up to 5 m and a leaf weight of up to 300 kg
- Digitally adjustable leaf movement force, slowdown position and the resistance at which the direction of movement is reversed
- Memory for up to 548 remote controls at 433.92 MHz, PIN code protection possible
- Remote control functions: step-by-step, open + stop, close + stop, open, close, stop, pedestrian gate
- Automatic gate closing after a set time, soft start and stop
- Deleting a remote control from the control unit memory without the remote itself, if its position in memory is known, and remote cloning
- Operating cycle counter
- The packaging contains additional filling that secures the operator during transport
Technical data
| Brand | GISE |
| Product line | GISE Home |
| Power supply | 230 V AC 50 Hz ±10 % |
| Motor | 250 W, 230 V AC 50 Hz |
| Maximum current consumption | 1.2 A |
| Gate opening width | up to 5 m |
| Maximum gate leaf weight | 300 kg |
| Maximum double gate weight | 600 kg |
| Minimum post width | 8 cm |
| Drive dimensions | 760 (1196 with extended piston) × 174 × 102 mm |
| Operator weight | 5.8 kg |
| Piston stroke | 400 mm |
| Rod extension speed | 1.6 cm/s |
| Operating temperature | −45…+65 °C |
| Degree of protection | IP44 |
| Power cable length | 1000 mm |
| Remote control memory | 548 remotes |
| Remote control frequency | 433.92 MHz |
| 230 V AC outputs | 3 (for controlling the operators and the signal lamp) |
| Low-voltage multifunction outputs | 4 |
| Safety inputs | 2 (for photocells) |
| Control inputs | 3 |
| Limit switches | no |
| Gate control via app | no |
| Usage type | residential |
Gate operators have no mains plug: they are wired into the building's electrical installation, so under the regulations they may only be installed by a qualified professional with the appropriate permits.