| DC voltage measurements: |
200 mV ± (0.1% + 8) @ 0.01 mV , 2 V ± (0.1% + 8) @ 0.0001 V , 20 V ± (0.1% + 8) @ 0.001 V , 200 V ± (0.1% + 8) @ 0.01 V , 1000 V ± (0.15% + 8) @ 0.1 V |
| AC voltage measurements: |
2 V @ 0.0001 V : ± (0.8% + 40) @ 45 Hz … 1 kHz ± (3% + 40) @ 1 kHz … 10 kHz ± (7% + 40) @ 10 kHz … 100 kHz 20 V @ 0.001 V : ± (0.8% + 40) @ 45 Hz … 1 kHz ± (3% + 40) @ 1 kHz … 10 kHz ± (7% + 40) @ 10 kHz … 100 kHz 200 V @ 0.01 V : ± (0.8% + 40) @ 45 Hz … 1 kHz ± (5% + 40) @ 1 kHz … 10 kHz 1000 V @ 0.1 V : ± (1.5% + 40) @ 45 Hz … 1 kHz ± (6% + 40) @ 1 kHz … 5 kHz ± (10% + 40) @ 5 kHz … 100 kHz |
| DC current measurements: |
200 µA ± (0.2% + 20) @ 0.01 µA , 2000 µA ± (0.2% + 20) @ 0.1 µA , 20 mA ± (0.2% + 20) @ 0.001 mA , 200 mA ± (0.2% + 20) @ 0.01 mA , 10 A ± (0.8% + 30) @ 0.001 mA |
| AC current measurements: |
200 µA @ 0.01 µA : ± (1% + 15) @ 45 Hz … 1 kHz ± (2% + 40) @ 1 kHz … 10 kHz 2000 µA @ 0.1 µA : ± (1% + 15) @ 45 Hz … 1 kHz ± (2% + 40) @ 1 kHz … 10 kHz 20 mA @ 0.001 mA : ± (1% + 15) @ 45 Hz … 1 kHz ± (2% + 40) @ 1 kHz … 10 kHz 200 mA @ 0.01 mA : ± (1% + 15) @ 45 Hz … 1 kHz ± (2% + 40) @ 1 kHz … 10 kHz 10 A @ 0.001 A : ± (2% + 20) @ 45 Hz … 1 kHz ± (2% + 40) @ 1 kHz … 10 kHz |
| Active resistance measurements: |
200 Ω ± (0.5% + 20) + test lead resistance @ 0.01 Ω , 2 kΩ ± (0.5% + 20) @ 0.0001 kΩ , 20 kΩ ± (0.5% + 20) @ 0.001 kΩ , 200 kΩ ± (1% + 20) @ 0.01 kΩ , 2 MΩ ± (1% + 40) @ 0.0001 MΩ , 20 MΩ ± (1.5% + 40) @ 0.001 MΩ |
| Capacitance measurement: |
20 nF ± (1.5% + 20) + test lead capacitance @ 0.001 nF , 200 nF ± (1.5% + 20) @ 0.01 nF , 2 µF ± (1.5% + 20) @ 0.0001 µF , 20 µF ± (1.5% + 40) @ 0.001 µF , 400 µF ± (1.5% + 40) @ 0.01 µF , 2 mF ± (5% + 40) @ 0.0001 mF 20 mF @ 0.001 mF |
| Inductance measurement: |
- |
| Frequency measurement: |
20 Hz ± (0.1% + 15) @ 0.001 Hz 200 Hz ± (0.1% + 15) @ 0.01 Hz 2 kHz ± (0.1% + 15) @ 0.0001 Hz 20 kHz ± (0.1% + 15) @ 0.001 Hz 200 kHz ± (0.1% + 15) @ 0.01 Hz 2 MHz ± (0.1% + 15) @ 0.0001 MHz 20 MHz ± (0.1% + 15) @ 0.001 Hz 200 MHz @ 0.01 MHz |
| Temperature measurements: |
- |
| Automatic change of measuring ranges: |
- |
| hFE: |
- |
| Diode test: |
- |
| Continuity test signal: |
- |
| Checking the TTL status: |
- |
| RS-232: |
- |
| USB: |
- |
| Selected characteristics: |
Freezing of the last reading, freezing of the highest or lowest measurement, Writing the value peak, REL – relative measurement mode, Analog bar graph, Ability to store readings, access the stored results and send them to a computer via the USB interface, Large, readable and backlit LCD display, Low battery indication, Aesthetic design, Short test leads with crocodile clips included in the kit, Practical carrying case included in the kit |
| Power supply: |
Battery 9V, type 6F22 – included |
| Weight: |
0.35 kg |
| Size: |
203 x 93 x 40 mm |
| Manufacturer / Brand: |
UNI-T |
| Warranty: |
2 years |