Skip to main content

* The appearance of the product may differ from what is shown in the picture

SATEL PERFECTA 32-WRL LTE SET-A control panel

Product code: 23463

EAN: 5905033337176

Piegādes laiks: 11-13 Martā

Estimated Delivery Dates

258,59 

Availability: 0

Satel PERFECTA 32-WRL LTE SET-A kit (motherboard, antenna, housing)

The set includes:

  • PERFECTA motherboard 32 Lte
  • antenna
  • body

Goal

Amīlija houses, terraced house segments, offices, small businesses, etc. They provide protection according to the requirements of EN 50131, level 2. Allows create a wired and wireless installation (frequency band 433 MHz). Radio transmissions are sent bidirectionally (with PRF-LCD-WRL wireless manipulators and MSP-300 R sirens) or unidirectionally (with MICRA series detectors and MPT-350 remote controls). Wireless communication makes it easy to expand an existing system without laying additional cables.

In the model PERFECTA 32 LTE uses a mobile phone that supports data transmission in LTE* technology. It provides cooperation with a mobile application with support for PUSH messages, remote system configuration using the PERFECTA Soft program, event monitoring (for example, to a security agency monitoring station), voice notifications, SMS control and audio verification (listening to sounds from the protected object). It supports two nano-SIM cards, which ensure continuity of communication: if there is no connection to the first operator's network, the second card is automatically selected.

The control panel electronics board is equipped with 8 inputs and 4 wired outputs. Their number can be increased by connecting expansion modules: INT-E input expanders and INT-O or INT-ORS output expanders. This allows you to expand the system by adding more sensors, alarms, and even actuators (to control garage doors, roller shutters, garden sprinklers).

The control panel allows you to divide the system into two zones, choosing from three standby modes (day, night, full). Each input can be assigned to one or both monitored zones.

The system can be configured in two ways: from a computer with the PERFECTA Soft program installed (locally – connection via RS-232 (TTL) port, remotely – via data transmission over a mobile network*) and using the keyboard, using key sequences in the service menu.

* support for data transmission in LTE/HSPA+/EDGE/GPRS technology - depending on mobile network capabilities

Key features:

from up to 5 0liance 32 programmable wired inputs:

-configuration selection: NO, NC, EOL, 2EOL/NO, 2EOL/NC

-ability to support roller shutters and vibration sensors

  • from 4 to 12 programmable wired outputs
  • 2 power outputs on the main board 2 nano-SIM sockets (SMS, monitoring to the station, mobile application, PUSH notifications)

    -voice (play voice messages for phone notifications)

    -acoustic alarm test (listening to sounds)

    -radio operating at 433 MHz

    • support for encrypted wireless communication with PRL3 key and PRL0 key R alarm

      -one-way with MICRA series detectors and MPT-350 remote controls

      • division of the system into 2 zones:

      -3 monitoring modes per zone

      -possibility to assign entry to two zones

      -user control (LCD control)

      ) or via PLL-key bus. expansion modules (INT-E, INT-O, INT-ORS) and 433 MHz remote control expander (INT-RX-S)

    • system management using:

    -prf-lcd keyboards (up to 4)

    -perfecta management mobile application

    -remote control operating in the 433 MHz band (up to 15) -requires cooperation with the int-rx-s module

    • 15 User passwords

      -1 Service password

      • Name editing (users, zones, inputs, outputs and modules), facilitating system management and monitoring
      • 8 timers with the ability to set exceptions. ul>

        -overload protection

        -protection against complete battery discharge

        -battery charging current regulation

        • Programming the control panel settings:

        -locally – keyboard or computer with PERFECTA Soft program installed, connected to the RS-232 (TTL) port of the control panel

        -remotely – computer with PERFECTA Soft program, using installation, using

        data transmission using

        management network.

        °C

        Batter>

        5 VDC power battery

        current

        14V DC

        current

        14V DC

        current

        14V DC

        current

        14V DC

        current

        14V DC

        current

        Additional information

        Voice messages 16
        Memory events 3584
        Zones 2
        Timers 8
        Electronics board dimensions 160×110>temperature range 5-5 mm
        Supply voltage 18 V AC, 50-60 Hz
        Standby power consumption 240mA
        Maximum power consumption 63 mA
        Weight 154 g
        Maximum humidity 93±3%
        Battery failure signal voltage 11 V
        32
        Programmable wired outputs 4
        Maximum number of programmable outputs 16
        Power outputs 2>2 communications 1
        Manipulators Up to 4
        Protection level EN 50131 Grade 2
        AUX output load power. repaired transformer 40VA
        Users 15
        KPD output load 500 mA / 12 V DC
        Output voltage range 500mA
        Power supply output voltage 12 V DC ±15%
        Telephone numbers for notification 8
        The output power of the power supply is programmable. Low output 25 mA / 12 V DC
        Load capacity of high-current programmable outputs 1000 mA / 12 V DC
        Battery power consumption in standby mode 15> 150mA

        14V DC

        battery charging current 500mA
        power supply output voltage 12vdc ±15%
        2a
        low current load capacity programmable outputs 25 mA/12 V DC
        The high-current load capacity is determined by the battery. 150mA
        battery charging current 500mA
        power supply output voltage 12vdc ±15%
        2a
        low current load capacity programmable outputs 25 mA/12 V DC
        The high-current load capacity is determined by the battery. 150mA
        battery charging current 500mA
        power supply output voltage 12vdc ±15%
        2a
        low current load capacity programmable outputs 25 mA/12 V DC
        The high-current load capacity is determined by the battery. 150mA
        battery charging current 500mA
        power supply output voltage 12vdc ±15%
        2a
        low current load capacity programmable outputs 25 mA/12 V DC
        The high-current load capacity is determined by the battery. 150mA
        battery charging current 500mA
        power supply output voltage 12vdc ±15%
        2a
        low current load capacity programmable outputs 25 mA/12 V DC
        The high-current load capacity is determined by the battery. 150mA
        battery charging current 500mA
        power supply output voltage 12vdc ±15%
        2a
        low current load capacity programmable outputs 25 mA/12 V DC
        The high-current load capacity is determined by the battery. 150mA
        Svars 2,0000 kg
0
Shopping cart
Shopping cart is emptyReturn to Shop